Providers of laser
components and laser
related accessories
LabMax-TO Laser Power Meter and Laser Energy Meter has been discontinued.
Please click here for the LabMax-Touch 2256258LabMax-TOP Laser Power Meter and Laser Energy Meter LabMax-TOP Laser Power Meter and Laser Energy Meter (RoHS)
For thermal, pyroelectric, and optical sensors; measures energy up to 10000 pps.
Measures laser power and energy Ergonomic design enhances user experience Compatible with LM- and PM-model thermopile and optical sensors with beam position display Pulse energy to 10 kHz Data logging to onboard memory and USB flash drive USB and RS232 PC interfaces RoHS Compliant The LabMax laser power meter is appropriate for anyone who needs to analyze and monitor laser output. Data analysis can be achieved via statistical and trend analysis and stored in onboard flash memory for future retrieval with the File Manager tool. Data can also be analyzed directly on a PC through USB and RS232 serial connections, or by logging data to a USB flash drive attached directly to the meter. Installable applications software and LabView ® drivers are provided to support PC interfacing. The LabMax display and meter can be positioned at many different angles so customers can place it within the limited bench space typically available in a laser lab and still easily view the display.
The LabMax-TOP laser power meter is directly compatible with most Coherent thermal, pyroelectric and semiconductor sensors and displays beam position for quick and accurate setup. These sensors offer wavelength coverage from 190 nm to 12 µm, measure from nW to kW, nJ to J, and from single shot to 10 kHz.
Name |
LabMax-TOP |
Input Range, Thermopile Sensors |
20 µV to 2V (PM Model) |
Input Range, Optical Sensors |
1 nA to 20 mA |
Input Range, Pyroelectric Sensors |
1 mV to 16V |
Measurement Resolution |
0.1% of full-scale |
Noise, Thermopile Sensors |
1.2 µV (LM Model) |
Noise, Optical Sensors |
4.6 pA |
Noise, Pyroelectric Sensors |
20 µV |
Max Repetition Rate (Hz) |
10,000 sampling (1,000 Hz every pulse) |
Power Sampling Rate |
10 Hz |
Accuracy (Digital Meter) |
±1.0% of reading |
Accuracy - System |
Meter accuracy + sensor accuracy |
Accuracy - Analog Output |
±1.0% |
Display |
112 x 78 mm backlight graphic LCD, 480 x 320 pixels. Adjustable contrast and viewing angle |
Statistical Analysis |
Min., max., mean, range, standard deviation, energy dose, and stability. Trend charting, tuning, positional display, and analysis of beam stability |
Computer Interface |
USB and RS-232 (-TOP and -TO models) |
Analog Output |
0 to 1, 2, or 4 VDC (selectable) |
Analog Output Update Rate |
Up to 1,000 Hz for pyroelectric; 10 Hz for thermopile and optical |
Trigger |
External trigger or internal trigger (2-20% of full scale, selectable) |
Instrument Power |
90 to 260 VAC, 50/60 Hz AC power adapter (incl.) |
Battery Life |
4400 mAH Li-ion battery (without backlighting) |
Temperature (Operating) |
5°C to 40°C (41°F to 104°F) |
Temperature (Storage) |
-20°C to 70°C (-4°F to 158°F) |
Size (H x W x D) |
152 x 229 x 53 mm (6.0 x 9.0 x 2.1 in.) |
Part Number |
1104622 |
Part Number |
Description |
Power Range (W) |
Power Resolution (W) |
Max Pulse Length (S) |
Max Joules |
Min Joules |
---|---|---|---|---|---|---|
COH1098304 |
LM-10 HTD Sensor |
0.01-10 |
0.001 |
0.11 |
10 |
.05 |
COH1098320 |
LM-45 HTD Sensor |
0.1-45 |
0.01 |
0.12 |
10 |
.07 |
COH1098328 |
LM-3 HTD Sensor |
0.01-3 |
0.001 |
0.11 |
10 |
.05 |
COH1098394 |
LM-150 FS HTD Sensor |
0.1-150 see note 1 |
0.01 |
0.12 |
10 |
.07 |
COH1098404 |
LM-30 V Sensor |
0.1-30 |
0.01 |
0.17 |
10 |
.07 |
COH1098456 |
LM-20 HTD Sensor |
0.1-20 |
0.01 |
0.12 |
10 |
.07 |
note 1 - Intermittent duty
Part Number |
Description |
Max Power (W) |
Active Area Diameter (mm) |
Max Average Power Density (kW/cm2) |
Max Pulse Energy Density (J/cm2> |
---|---|---|---|---|---|
COH1098329 |
PM2 Sensor |
2 |
19 |
26 |
0.6 |
COH1097901 |
PM10 Sensor |
10 |
19 |
26 |
0.6 |
COH1098314 |
PM30 Sensor |
30 |
19 |
26 |
0.6 |
COH1098498 |
PM30X Sensor |
30 |
19 |
26 |
0.6 |
COH1098329 |
PM100-19C Sensor |
100 |
19 |
26 |
0.6 |
COH1098444 |
PM150-19C Sensor |
150 |
19 |
26 |
0.6 |
Part Number |
Description |
Energy Range |
Active Area Diameter (mm) |
Max Average Power (W) |
Max Rep. Rate (pps) |
---|---|---|---|---|---|
COH1110855 |
J-10B-LE Sensor |
300 nJ - 600 µJ |
10 |
4 |
1000 |
COH1110843 |
J-10B-HE Sensor |
10 µJ - 29 mJ |
10 |
4 |
1000 |
COH1110743 |
J-25B-LE Sensor |
25 µJ - 50mJ |
25 |
5 |
1000 |
COH1110746 |
J-25B-HE Sensor |
500 µJ - 1 J |
25 |
5<
/TD>
| 1000<
/TD>
|
COH1110576 |
J-50B-LE Sensor |
250 µJ - 500 mJ |
50 |
10 |
300 |
COH1110573 |
J-50B-HE Sensor |
1 mJ - 2 J |
50 |
10 |
300 |
Common characteristics