LabMax-TO Laser Power Meter (RoHS)
For thermal and optical sensors; displays beam position when using LM Series heads.
Measures Laser Power Ergonomic design enhances user experience Compatible with LM- and PM-model thermopile and optical sensors with beam position display Data logging to onboard memory and USB flash drive USB and RS232 PC interfaces RoHS Compliant The LabMax laser power meter is appropriate for anyone who needs to analyze and monitor laser output. Data analysis can be achieved via statistical and trend analysis and stored in onboard flash memory for future retrieval with the File Manager tool. Data can also be analyzed directly on a PC through USB and RS232 serial connections, or by logging data to a USB flash drive attached directly to the meter. Installable applications software and LabView ® drivers are provided to support PC interfacing. The LabMax display and meter can be positioned at many different angles so customers can place it within the limited bench space typically available in a laser lab and still easily view the display.
The LabMax-TO laser power meter is directly compatible with most Coherent thermal and semiconductor sensors and displays beam position for quick and accurate setup. These sensors offer wavelength coverage from 190 nm to 12 µm and measure from nW to kW.
Name |
LabMax-TO |
Input Range, Thermopile Sensors |
50 µV to 2V (LM Model) |
Input Range, Optical Sensors |
1 nA to 20 mA |
Measurement Resolution |
0.1% of full-scale |
Noise, Thermopile Sensors |
1.2 µV (LM Model) |
Noise, Optical Sensors |
4.6 pA |
Power Sampling Rate |
10 Hz |
Accuracy (Digital Meter) |
±1.0% of reading |
Accuracy - System |
Meter accuracy + sensor accuracy |
Accuracy - Analog Output |
±1.0% |
Display |
112 x 78 mm backlight graphic LCD, 480 x 320 pixels. Adjustable contrast and viewing angle |
Statistical Analysis |
Min., max., mean, range, standard deviation, energy dose, and stability. Trend charting, tuning, positional display, and analysis of beam stability. |
Computer Interface |
USB and RS-232 |
Analog Output |
0 to 1, 2, or 4 VDC (selectable) |
Analog Output Update Rate |
Up to 1,000 Hz for pyroelectric; 10 Hz for thermopile and optical |
Instrument Power |
90 to 260 VAC, 50/60 Hz AC power adapter (incl.) |
Battery Life |
8800 mAH Li-ion battery |
Temperature (Operating) |
5°C to 40°C (41°F to 104°F) |
Temperature (Storage) |
20°C to 70°C (-4°F to 158°F) |
Size (H x W x D) |
152 x 229 x 53 mm (6.0 x 9.0 x 2.1 in.) |
Part Number |
COH1104619 |
Part Number |
Description |
Power Range (W) |
Power Resolution (W) |
Max Pulse Length (S) |
Max Joules |
Min Joules |
---|---|---|---|---|---|---|
COH1098304 |
LM-10 HTD Sensor |
0.01-10 |
0.001 |
0.11 |
10 |
.05 |
COH1098320 |
LM-45 HTD Sensor |
0.1-45 |
0.01 |
0.12 |
10 |
.07 |
COH1098328 |
LM-3 HTD Sensor |
0.01-3 |
0.001 |
0.11 |
10 |
.05 |
COH1098394 |
LM-150 FS HTD Sensor |
0.1-150 |
0.01 |
0.12 |
10 |
.07 |
COH1098404 |
LM-30 V Sensor |
0.1-30 |
0.01 |
0.17 |
10 |
.07 |
COH1098456 |
LM-20 HTD Sensor |
0.1-20 |
0.01 |
0.12 |
10 |
.07 |
Part Number |
Description |
Max Power (W) |
Active Area Diameter (mm) |
Max Average Power Density (kW/cm2) |
Max Pulse Energy Density (J/cm2> |
---|---|---|---|---|---|
COH1098329 |
PM2 Sensor |
2 |
19 |
26 |
0.6 |
COH1097901 |
PM10 Sensor |
10 |
19 |
26 |
0.6 |
COH1098314 |
PM30 Sensor |
30 |
19 |
26 |
0.6 |
COH1098498 |
PM30X Sensor |
30 |
19 |
26 |
0.6 |
COH1098329 |
PM100-19C Sensor |
100 |
19 |
26 |
0.6 |
COH1098444 |
PM150-19C Sensor |
150 |
19 |
26 |
0.6 |